7 FAULT TRACING
WARNING
ELECTRIC SHOCKS CAN KILL Ensure that the mains voltage supply to the
machine has been disconnected externally. Switch off the switch at the mains
socket before inspecting or working in the power source.
WARNING
Plasma cutting equipment uses extremely high voltages that can cause severe injury
or even death. Observe extreme caution when working with the covers removed.
Try these recommended checks and inspections before sending for an authorized
service technician.
Type of fault Corrective action
No arc. S Check that the mains power supply switch is
turned on.
S Check that the current supply and return
cables are correctly connected.
S Check that the correct current value is set.
The current is interrupted during cutting. S Check whether the thermal overload trips
have operated.
S Check the mains power supply fuses.
The thermal cut-out trips frequently. S Make sure that you are not exceeding the
rated data for the power source (i.e. that the
unit is not being overloaded).
Poor cutting performance. S Check that the current supply and return
cables are correctly connected.
S Check that the correct current value is set.
S Check that the correct electrode is being
used.
S Check the mains power supply fuses.
If you cannot locate the problem switch off the incoming power supply, open the unit
and check all components and conductors visually. Look for swollen or leaking
condensers and other signs of damage or discolouration.