bp15da3
MAKE SURE POWER SWITCH ON CONSOLE IS IN OFF POSITION
AND PRIMARY INPUT POWER IS DE-ENERGIZED.
6.10 Remote junction box installation
The Remote Junction Box (RJB) provides a means to extend the total length of the
PT-37 Torch. A Remote Junction Box is used in combination with 50’, 75' or 100’
extension cable and any standard length of PT-37 Plasma Torch from 4.5’ to 50’, to
create a combined maximum torch length of 150 feet.
Installation of a Remote Junction Box requires minor modifications to the ESP-101
power supply, mounting of the box itself, and connection of the extension cable. Use
the diagram and steps below for installation.
Note:
See section 5.6 “System and optional accessoreis” for remote junction box and
extension cable ordering information
3-phase W / ground
ESP-101
PT-37 Torch
Remote junction
box
Extension
cable
4,5”, 17”,
25”, 50”
50”, 75”, 100”
Figure 3-7. Connection diagram for remote junction box
Description of ESP-101 modification: The wiring modification (interconnect plug
reversal) redirects the control signal from the ESP-101 internal solenoid, to the pins
within the torch connection panel receptacle. The control signal is then diverted to
the solenoid within the remote junction box
The hose modification (solenoid air bypass) directs the system air supply to the
solenoid within the remote junction box. This ensures air at a sufficient pressure is
immediately available to the PT-37 torch.
6.11 ESP-101 modifications
Remove the top and right side panel of the power supply.