460
Figure 5.1 IGBT Gating Signal
5.2 REFERENCE VOLTAGE CHECKS
A. Control Board Assembly (PCB1)
1. LED’s
LED- (D9) - Torch Switch
LED- (D4) - Pilot Arc Relay
LED- (D1) - Gas Solenoid Valve
2. Voltage Test Points
Tests are made with power on - no arc.
Disable High Frequency by disconnecting blue wire with black sleeve
TP-1 - Torch trigger signal
TP-4 - IGBTs driving signal - switching frequency = 18.5 KHz
TP-5 - IGBTs driving signal - switching frequency = 18.5 KHz
TP-7 - +5 vdc
TP-8 - +15 vdc
TP-9 - -15 vdc
TP-10 - Ground
54 µs
13vdc
13vdc
0
SECTION 5 TROUBLESHOOTING